Cold Lip Effusion Cell CLC
The cold lip effusion cell is designed to evaporate materials like aluminium which tend to creep out of the crucible due to wetting of the PBN surface. The cold orifice results in a long lifetime of the cell and a low defect concentration in the epitaxial layers.
Technical Data:
Type | CLC |
Heating system | Radiation heating, tantalum wires with PBN insulators |
Temperature range | 200°C … 1400°C |
Temperature stability | ≤0.1°C depending on the PID controller |
Max. outgas temp. | 1600°C |
Max. power | 220 W (NW 40 CF) |
Max. current | 8A |
Bakeout temperature | 250°C |
Conditioning | Heated to maximum temperature with and without crucible |
Shipping | Stainless steel container with valve |
Standards:
Flange size | CF40 / CF63 or specified |
Max outer diameter | 38mm / 61mm or specified |
Length | 283.5mm or specified |
Thermocouple | Type C or specified |
Crucible material | PBN / PGR / W / Ta / Mo / quartz |
Crucible capacity | 5 - 40 cc |
Options:
- Molybdenum version
- Crucibles with different inserts
- Downward looking version
- Integrated shutter
- Water cooling
Available Downloads:
For further information, please contact
sales(at)createc.de.